IMDAD
HA Fillers
Mesh Threads

The GentleMax Pro Plus Effect

Patients will notice hair falling & reduction in hair count starting from 1st session.

    The science behind GentleMax Pro Plus
    Hair life cycle

    Alexandrite laser wavelengths has high absorption on melanin, when laser is absorbed, the energy thermally damages bulge & bulb cells, these cells are responsible for hair growth and removing them prevents future hair regrowth.

    The hair is rich in melanin & has a life cycle of 3 stages:

    • Anagen: this growing stage is the ideal target of laser hair removal, the hair is fully attached to the bulge & bulb cells which can be thermally damaged by burning the hair.
    • Catagen & Telogen: hair in this stage stops growing and is not attached to the bulge & bulb cells, hence burning hair by laser doesn't remove bulge & bulb cells,. These cells can be removed once the hair cycle returns to anagen stage, which explains the need for multiple sessions.
    Targeting melanin in hair

    Hair removal lasers target melanin which is present in both hair & skin, hence a protection of skin from the thermal effect is needed. Hair removal lasers use different cooling technologies to cancel the thermal effect of laser & protect skin.

    Candela's proprietary Dynamic Cooling Device (DCD) cools the skin precisely & consistently in a way that prevents under-cooling of skin that may cause burns, and over-cooling that may leak to hair itself & affect results.

    Hair removal efficacy

    Efficacy of hair removal necessitates using a pulse duration shorter than the Thermal Relaxation Time (TRT) of hair, when achieved, the hair gains temperature faster than losing it till it reaches the burning point.

    The TRT of the hair depends on its size, smaller hairs have low TRT which needs low pulse duration to reach the burning point.

    GentleLase PRO avails 3 msec, the lowest pulse duration in hair removal supported by the high protection by the patent DCD cooling, which makes it effective in thick & resistant thin hair.

    Vascular removal
    Oxyhemoglobin absorbs a portion of Nd:YAG laser energy, when laser is used with high enough energy, the vessels supplying the lesion with blood can be targeted and destroyed. Over few treatments the vascular lesion disappears, and the skin appearance improves.
    GentleLaser provides an optional 1.5 & 3.0 mm hand piece that enables treating small vascular lesions & blue veins with accuracy & efficacy.
    Interested to know more about the product?
    Features & Benefits
    GMAX feature 1
    Faster than ever
    GentleMax Pro Plus provides a treatment faster by 47% than the previous generation. With the combination of 26mm spot size and the 2.5 Hz repetition rate, you can now treat more patients every day for a higher ROI
    Bursts Thin Hair
    GenlteMax Pro Plus provides a very low pulse duration of 2 msec with 38% more fluence than its predecessor. This provides excellent clearance of thin & thick hair in the lowest number of sessions and without ending with resistant hair
    GMAX feature 2
    Consistent automatic cooling
    The DCD spray amount is set before starting the treatment & is equally sprayed with each pulse. Other cooling types are user dependent: slow movement may over cool the follicle & compromise results, whereas fast movement will lead to insufficient cooling of skin & burn risks.
    GMAX feature 3
    Cost-effective investment
    The laser head in GentleLaser works up to a very high pulses count, when combined with its durability & long lifetime, it represents a safe investment with high returns.
    GMAX feature 6
    For all skin types
    GentleLaser provides suitable choices for every patient, Alexandrite is more effective in fair skin types, Nd:YAG is safe in dark skin types...single wavelength is used in each pulse to match patient need & avoid unnecessary costs.
    GMAX feature 7
    Guided accuracy
    The detachable hand-piece tip design facilitates precise operation and minimizes human error by providing: a clear visibility of the treated area, simple shooting steps & a fixed perpendicular angle.
    GMAX feature 9
    Matches small areas
    GentleLaser comes with nine spot sizes from 6-24 mm, these several spot size choices facilitate matching the size of different areas like the bikini line & beard shaping with ease.
    GMAX feature 10
    No Compromises
    GentleLaser allows combining biggest spot size, best pulse duration & highest repetition rate at any fluence. In other lasers, an increase in a particular parameter forces a decrease in other ones.
    GMAX feature 12
    The cold laser
    The DCD cooling enables a comfortable & highly safe treatments that has become known by patients as "The Cold Laser".
    Want more details?
    View Site in Mobile | Classic
    Share by: